英语翻译1.power on.Switch to setup.switch to THK.2.Loosen upper

问题描述:

英语翻译
1.power on.Switch to setup.switch to THK.
2.Loosen upper probe clamp knob.Check that top probe is lowered against support arm.Re-tighten probe.
3.Insert .0625”gage block under probe.
4.Using probe adjustment wheel,lower top probe to touch block.
5.Raise top probe slightly to remove .0625”block.Inset.050”block.
6.Loosen bottom probe,adjust to barely touch block.Withdraw probe until O/R light just goes out.
7 Observe meter.Withdraw lower probe further until meter reading drops by approx.2.00”.Clamp probe and remove block.
1个回答 分类:综合 2014-12-13

问题解答:

我来补答
1.power on.Switch to setup.switch to THK.接通电源,将开关转到“setup”位置,再转到“THK”位置.
2.Loosen upper probe clamp knob.Check that top probe is lowered against support arm.Re-tighten probe.松开上面的探测器制动旋钮,检查上部探测器是否下降抵住支撑臂.再次旋紧上部探测器.
3.Insert .0625”gage block under probe.将0.0625"的测量块插到探测器下方.
4.Using probe adjustment wheel,lower top probe to touch block.使用探测器调节轮,使顶部探测器触碰到测量块.
5.Raise top probe slightly to remove .0625”block.Inset.050”block.微微上移顶部探测器,移除0.0625"的测量块,再插入0.050"的测量块
6.Loosen bottom probe,adjust to barely touch block.Withdraw probe until O/R light just goes out.松开底部探测器,调节至刚脱离测量块.向外抽测量块直至O/R指示灯熄灭.
7 Observe meter.Withdraw lower probe further until meter reading drops by approx.2.00”.Clamp probe and remove block.观察仪表.进一步向外抽测量块直至仪表读数回落至2.00左右.用钳子夹住测量块并移除.
(测量块是否就是试块?)
希望加分哦.
 
 
展开全文阅读
剩余:2000
下一页:生物 酶